Energy & EnvironmentBreakthroughs
Researchers at KIT have built the first elastocaloric cooling system driven entirely by heat, using nickel-titanium shape memory films to convert waste heat into cooling without electricity.
In a prototype that is small enough to be lost in your pocket there are two wires made of nickel-titanium, each thinner than a hair on your head. If you stretch one and at the same time release the other, an unusual thing occurs: one gets warmer and the other colder. There is no compressor working away, no refrigerant moving around in the pipes, and no motor at all. Heat is introduced at one end and cold emerges at the other.
The researchers from the Karlsruhe Institute of Technology, in collaboration with those at the University of Tsukuba, have just published it in Nature Energy: the very first elastocaloric cooler that operates using heat alone.
That seems like a trick that physicists might pull. It isn’t. Think about all the heat we currently waste into the atmosphere - through engine blocks, from server racks, out of factory chimneys - and altogether the situation looks a lot more interesting.
About half of the world’s total energy consumption is used for cooling. Traditional air conditioners, refrigerators, and cooling systems for data centres all use electric compressors that circulate refrigerants, many of which are potent greenhouse gases. The International Energy Agency forecasts that cooling demand will increase three-fold due to temperatures. The search for alternatives that use less electricity or no electricity at all is not merely minor. One possible solution is the elastocaloric cooling system developed at KIT.
Elastocaloric cooling is nothing new, since it has for a long time been known that certain shape-memory alloys cool when a mechanical load is removed. The problem has always been that an electric motor or an actuator is still required in order to apply and release that load. Dr Jingyuan Xu’s team have now found a method of overcoming this limitation by splitting the task between two films.
The first film makes use of the shape-memory effect in that when it is heated it contracts and thus converts thermal energy directly into mechanical work. This contraction then has an effect on the second film, causing it to be loaded and unloaded repeatedly. As a result of each cycle, reversible changes take place in the crystal structure of the second film and it draws heat from the surroundings, producing a cooling effect that can be detected. In their prototype the two people obtained a temperature change of almost 13 degrees Celsius at the material level and 4 degrees Celsius at the device level when the temperature was raised to 86 degrees Celsius.
The engineering aspect involves the intersection of materials science, thermodynamics, and mechanical design, and therefore requires a more detailed examination of shape-memory alloys and how they store and release energy.
Nickel-titanium (NiTi), known commercially as Nitinol, is the shape-memory alloy most often used. It has two crystal structures: austenite (the high-temperature phase with a cubic structure) and martensite (the low-temperature phase with a monoclinic structure). The transition between these two phases is reversible and is accompanied by the absorption or release of latent heat, a phenomenon that A-level Physics students will recognise from the changes of state in water, even though in this instance the change occurs entirely within a solid.
If you mechanically load a NiTi film while it is in the austenite phase, you cause it to transform into martensite, and this transformation gives off latent heat which warms the material. On removal of the load the material returns suddenly to its austenite form and takes in heat from its environment, as a result it cools down. This heat absorption is known as the elastocaloric effect and it can produce temperature changes of 20 degrees Celsius or more in one cycle.
A characteristic aspect of this prototype is that the first film acts as a thermal actuator rather than as a cooler. When heated above its transformation temperature (approximately 80 to 90 degrees Celsius for the alloy composition employed), it contracts significantly as it transforms from martensite to austenite. It is this contraction that performs the mechanical work required to load the second, cooler film. When the heat source is removed, the actuator film relaxes, thereby unloading the cooler film and producing the elastocaloric cooling effect.
The system’s efficiency is 84 per cent of its highest theoretically possible value (i.e., the Carnot coefficient of performance), a figure that is considerably higher than that achieved by vapour-compression systems with similar temperature differences. This high efficiency is partly because the phase change in NiTi is nearly a reversible thermodynamic process, involving only a small energy loss due to hysteresis.
The students taking A-level thermodynamics will be able to recognise the second law at work here since heat passes from the hot reservoir (in other words, the source of the waste heat) through the first film into mechanical work, and this mechanical work then produces a heat pump effect in the second film, transferring heat from a cold reservoir to a warmer one. Even though the total entropy of the system still increases, the arrangement allows low-grade waste heat to perform useful cooling work that, without the setup, would have to be done using electrical energy.
The biggest challenge now is scaling. Since the current prototype uses single films, its cooling capacity is limited. To increase the total heat transfer, the team is working on parallel arrays of films. The films also have to withstand millions of loading cycles without suffering fatigue failure, a possibility with NiTi but one that depends on careful control of film thickness, grain structure, and surface finish.
What’s going to happen next? The team’s idea is to use it for cooling the processor: a computer chip generates a lot of waste heat at temperatures well above those required for the actuator film to contract. A laptop or server that cooled itself by making use of its own exhaust heat, without having to employ fans or compressors, would be a completely new type of machine. Another area where it could be applied is in automotive electronics, since heat from the drivetrain is also always available there. Although making the technology large enough for room-sized air conditioning is still a longer-term goal, the physics shows that this is possible.